Settings (production list)

<< Click to Display Table of Contents >>

Navigation:  Reference Commands > F >

Settings (production list)

Previous pageReturn to chapter overviewNext page

 

Fitting list parameters can be determined here.

 

                                Access to the command over:

   

AutoCAD/BricsCAD

Allplan

 

Command line: _FLIDEF

 

Assistant: lueftung_gew | Ventilation | flisett

 

Toolbar: Ventilation | Interfaces | flisett

 

 

 

flidef

 

 

Dialogue-Options

 

Option

Description

Sorting

Sorts the parts.

 

Formula Number - The individual numbers are listed in consecutive formula numbers.

 

Position Number - The individual numbers are listed in consecutive position numbers.

 

Similar Parts summary - Identical parts are summary.

 

Individual Positions - Every part is shown in the list.

Drawing Transitions

 

Transitions can be drawn as rectangular to rectangular.

Ri/Ro

 

Sorts out the transitions rectangular&round.

Rectangular cross sections are shown at entrance or exit.

Straight Ducts

 

Serves to issue rectangular ducts.

 

yes - Fittings and straight ducts are issued.

 

no - Only fittings are issued.

 

only ducts - Only ducts are issued.

 

from/to - Limits the duct length to be issued.

Formula Number

 

Fittings to be issued can be defined with Formula numbers.

 

Round ducts - Acitvates&Deactivates round ducts for issuance.

Setting Fittings List Grid

 

3x3 - Shows 9 parts to a list (3 horizontal, 3 vertical).

 

2x2 - Shows 4 parts to a list (2 horizontal, 2 vertical).