<< Click to Display Table of Contents >> Easyline Starting-point Circulation |
Function to place the Circulation starting-point for the Easyline-System.
Access to the command over: |
AutoCAD/BricsCAD |
Allplan |
---|---|
Command line: _SETAP_Z
Assistant: | Circulation Easyline | |
Toolbar: Sanitary facilities | Circulation | |
After executing the function place one or more start points for the calculation in the drawing.
Start points can be freely moved, copied or deleted with the standard AutoCAD functions.
Option |
Description |
---|---|
New system layer
|
Layer for the generated pipeline can be assigned. The layer can be selected from the layer-selection. Here you are able to change the layer description. The color can also be selected. The settings from Layer definition for Systems and Trades are valid. |
Material |
The material and the minimum pipeline diameter can be selected. All heating materials stored in the Pipe tables can be used. |
Temperature Difference |
The temperature difference for a linegroup can be set (from the start point circulation to circulation load point, or from start point hot water to the circulation load point). The total temperature difference is twice the entered value (starting point hot water - circulation load point - starting point circulation). |
max. velocity |
The maximum velocity in m/s for dimensioning the pipeline. |
Heat Loss
|
The heat loss per running meter of pipeline is given in Watt. This value can be entered indepedent of basement pipelines (lines with an absolute height smaller than 0) and shaft lines (all other lines). These values can be set for the individual lines with the function Fix Exterior Temperature.. |
Overall Pressure Loss for Appliances |
An additional pressure loss (total pressure loss) for appliances and fittings can be set. |
Position |
The placement start point height can be given here.
Place height in drawing: When this function is activated, the height of the point picked is used for the start point. |