Easyline Starting-point Sanitary

<< Click to Display Table of Contents >>

Navigation:  Reference Commands > S > Set >

Easyline Starting-point Sanitary

Previous pageReturn to chapter overviewNext page

 

Here you are able to determine the start points for the Easyline system.

These start points contain all the necessary values for calculating a pipework system.

 

                                Access to the command over:

   

AutoCAD/BricsCAD

Allplan

 

Command line: _SETAP_S

 

Assistant: saniicon | Drinking water Easyline | S_VD_AP

 

Toolbar: Sanitary facilities | Sanitary Objects|sani_allplan_03

 

 

 

Two start Points (CW+HW) have to be set on the corresponding Easyline Systems.

 

SVD_Anfangspunkt

 

 

Dialogue-Options

 

Option

Description

CW/HW

 

Selection between the cold and hot water start points.

The temperature can be assigned.

New System Layer

 

A deactivated Checkbox: pipework is set in the active layer.

 

An activated Checkbox: an new layer can be set for the pipework to be calculated.

 

The layer can be selected and modified from the layer-selection with its description.

The color can also be modified.

The settings from Trade Definitions are valid.

Building Type

 

For the simultaneousness calculation of the building type.

Dimensioning

 

Shows with which criteria the pipework is to be set.

Dimensioning with R (pressure loss) or dimensioning with velocity are available.

R-value

 

The maximum useable (pipework -dimensioning) pressure loss per pipe-meter in Pa/m.

max. velocity

 

The maximum useable (pipework-dimensioning) velocity in m/s.

Max. Single Through-flow

 

The maximum single through-flow in l/s for the through-flow calculation.

Material

The material and the minimum diameter of the generated pipework can be selected.

All heating materials stored in the Pipe tables can be used.

The courseness of the material is shown.

other Medium

For the placement of a pipework, an alternative medium for density and viscosity can be used.

e.g. Cool pipes with "glycol mixture" or systems with "oil"

Position

By activating 'pick height in drawing', the Easyline-Start point is set on picked point. When deactivating this function, a new height can be entered.