Floor heating acc. to EN 1264 - CAD

<< Click to Display Table of Contents >>

Navigation:  Reference Commands > F >

Floor heating acc. to EN 1264 - CAD

Previous pageReturn to chapter overviewNext page

 

                                Access to the command over:

   

AutoCAD/BricsCAD

Allplan

 

Command line: _FBH_2

 

Assistant: heizung_gew | Underfloor Heating | fbh2

 

Toolbar: Heating | Underfloor Heating | fbh2

 

 

 

After calling up the function, choose the rooms you want to calculate:

fbh_047

 

 

Dialogue-Options

 

Option

Description

From CAD

Select the rooms per clicking on the room-symbol.

FBH_NEU_01

From Dialogue

Select the rooms over Dialogue:

FBH_NEU_02

Manage/Change Heating circles

The Dialogue "Underfloor Heating acc. to EN1264" opens.

 

 

After choosing the rooms the Dialogue "Underfloor heating acc. to EN1264" opens:

FBH_NEU_13

 

 

Dialogue-Options

 

Option

Description

Manufacturer and Distributor

Here you can edit the inputs for manufacturer and diostributor:

FBH_NEU_15

 

Pipe materials are save in directory %\k_data\heizung\en1264.

 

attentionOnly certificated CAD administrators are allowed to create or edit these files.

Flow/Return

FBH_NEU_14

Over fbh_vl a FL-overview is shown and the temperture can be changed.

Create new disrtibutor

Over the Context-menu you can create new distributors:

 

Heizkr_Vert

 

Dia

 

Add Heating circles

Now you can add rooms (graphically or over Dialogue) to the distributors.

 

Kont_Vert

 

Calculation

Recalculate distibutor (after room change):

The current distributor will be re-calculated with the changed distributor- and room data!

 

ATTENTION!

All Heating-circles of the distributor will be deleted and re-calculated!!!

 

Recalculate distributor (after change of Heating circle):

Only Heating circles will be recalculated.

 

Roombook and Properties:

FBH_NEU_70

 

 

Values in detail.

 

Heating circles

For the selected rooms heating circles will be calculated automatically.

Surface definitions and blind areas and border zones will be regarded.

Manufacturer, Pipe-separation and flooring will be taken from underfloor heating defaults, the temperature comes

from the room below.

The heating circles will be divided automatically, the pipe separation adapted.

Additional heatings are calculated automatically and already existing radiators are also included.

FBH_NEU_16

 

CAD-functions distributor

FBH_NEU_17

Here you can edit the Distibutor-Connections .

 

 

FBH_NEU_18

The distributor is set in CAD per picking two points.

FBH_NEU_23

 

 

 

Connect distributor:

Here you can connect the distributor.

 

 

Delete connections:

Select the loadpoints you want to delete and confirm with right mouse-button.

 

FBH_NEU_21

Supply pipes can be overtaken from CAD.

 

FBH_NEU_41

 

CAD-functions room

FBH_NEU_44

The dialogue "Room surfaces" opens.

Now you can define your heating area surfaces like shown in  "Specify heating surfaces graphically".

FBH_NEU_48

 

 

FBH_NEU_24

Heat circle desctiption and connection symbols are created --> see "Connect Distributor"

 

 

FBH_NEU_45

The Surface display can be edited here.

 

 

FBH_NEU_46

Draw Heat circles here.

 

 

FBH_NEU_47